翻訳と辞書
Words near each other
・ Sensory stimulation therapy
・ Sensory substitution
・ Sensory Sweep Studios
・ Sensory system
・ Sensory systems in fish
・ Sensory threshold
・ Sensory trick
・ Sensory unit
・ Sensory, Inc.
・ Sensory-motor coupling
・ Sensory-motor map
・ Sensory-specific satiety
・ Sensotronic Brake Control
・ Sensphal Khan
・ Sensing Murder
Sensing of phage-triggered ion cascades
・ SENSIO Technologies
・ SensiQ
・ Sensis
・ Sensis Agency
・ Sensistor
・ Sensitive
・ Sensitive (song)
・ Sensitive but unclassified
・ Sensitive Compartmented Information
・ Sensitive Compartmented Information Facility
・ Sensitive flame
・ Sensitive high-resolution ion microprobe
・ Sensitive New-Age Killer
・ Sensitive Pornograph


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Sensing of phage-triggered ion cascades : ウィキペディア英語版
Sensing of phage-triggered ion cascades
Sensing of phage-triggered ion cascades (SEPTIC) is a prompt bacterium identification method based on fluctuation-enhanced sensing in fluid medium. The advantages of SEPTIC are the specificity and speed (needs only a few minutes) offered by the characteristics of phage infection, the sensitivity due to fluctuation-enhanced sensing, and durability originating from the robustness of phages. An idealistic SEPTIC device may be as small as a pen and maybe able to identify a library of different bacteria within a few minutes measurement window.
==The mechanism==

SEPTIC utilizes bacteriophages as indicators to trigger an ionic response by the bacteria during phage infection. Microscopic metal electrodes detect the random fluctuations of the electrochemical potential due to the stochastic fluctuations of the ionic concentration gradient caused by the phage infection of bacteria. The electrode pair in the electrolyte with different local ion concentrations at the vicinity of electrodes form an electrochemical cell that produces a voltage depending on the instantaneous ratio of local concentrations. While the concentrations are fluctuating, an alternating random voltage difference will appear between the electrodes. According to the experimental studies, whenever there is an ongoing phage infection, the power density spectrum of the measured ''electronic noise'' will have a noise spectrum while, without phage infection, it is a 1/f noise spectrum. In order to have a high sensitivity, a DC electrical field attracts the infected bacteria (which are charged due to ion imbalance) to the electrode with the relevant polarization.〔

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Sensing of phage-triggered ion cascades」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.